Smart Room Control · RCU

Smart room control system

One controller behind every switch in the guest room: lighting scenes, air-conditioning, curtains and the Do Not Disturb / Make Up Room status — linked to the PMS and to housekeeping, installed and supported by our engineers in Singapore.

Master
9-ch I/O
5-ch relay
2-ch relay
1-ch relay
Power meter
12 V PSU
Air-con
Curtain
0-10 V dim
PWM dim
Infrared
RS485 gateway
Hover a module · click for its specs
In the Room

What it controls

Guests use one set of switches and a bedside panel. Behind them, the RCU runs the room to the hotel's rules.

Lighting scenes

One-touch scenes such as Welcome, Reading, Video and Sleep, with dimming and night-light logic for the bedside and bathroom.

Climate

Works with the hotel's HVAC: set-points and fan speed per scene, and an energy-saving setback when the room is empty.

Do Not Disturb / Make Up Room

Digital DND and MUR replace door hangers, and the status reaches housekeeping in real time.

Connected

Links to the hotel PMS, Bittel room phones, LG and Samsung hospitality TVs, room panels and our Opio3 platform.

Wall-mounted smart room control switch panel in a hotel room
For Engineering Teams

Built to be installed fast and kept running

  • Modular. Each function is its own DIN-rail module with its own chip, so one faulty module does not take the room down — swap it and it picks up its configuration automatically.
  • One RS485 bus. Switch panels share one bus with anti-collision, so two guests pressing switches at once still get a response in milliseconds. Bus, ring and star wiring all work.
  • Configured, not rewired. Scenes, timers and triggers (keycard, door contact, IR sensor, time of day) are set in the RCUTOOL software.
  • Remote upkeep. Firmware can be updated room by room or in batches, remotely or on site, and every module reports its working status.
Compared

RCU versus stand-alone room controls

 Prestige RCULegacy room controls
ConnectivityIntegrates with the hotel PMS, the Opio3 platform and room devices.Stand-alone control points with little data exchange.
EnergyOccupancy detection, HVAC setback and energy-saving modes.Manual control and little automation.
Guest experienceOne-touch scenes, bedside panel and digital privacy controls.Separate basic switches.
MaintenanceModular, with remote diagnostics.Complex wiring and more site visits.
ExpansionExtends to room phones, TVs, dashboards and other hotel systems.Limited upgrade path.
Modules

307 wired series — module reference

Main figures for each module. All modules mount on DIN rail and run on 12 V DC from the power module. Click a row to find the module in the cabinet view above.

ModuleWhat it doesMax currentSize (mm)
Master moduleRuns the room logic and configuration from the room management server and reports the status of every module. RS485 and TCP/IP; DHCP or static IP; remote firmware update.0.18 A87 × 105 × 51
9-channel I/OInputs and outputs for switch panels, IR sensor, door contact, doorplate, doorbell and door lock. 16 RJ45 ports (T568B).––
5-channel relayFive lighting circuits (incandescent, LED, halogen) and fans. Up to 500 W per channel, 1000 W per module.0.1 A87 × 105 × 51
2-channel relayTwo lighting or fan circuits. Up to 1000 W per channel, 2000 W per module.0.1 A69 × 105 × 51
1-channel relaySockets and outlets, switched with the I/O module. Up to 3000 W.0.1 A69 × 105 × 51
Power detectionMeasures the room's energy use and reports it to the management software. Up to 4000 W, 0.1 kWh resolution.0.049 A87 × 105 × 51
Power module90–264 V AC in, 12 V DC 2.1 A out for the other modules. CE, UL, RoHS.2.5 A (AC in)69 × 105 × 51
Air-conditioningFan-coil valve and low / medium / high fan speed, cooling and heating. Up to 1000 W per circuit, 2000 W total.0.14 A87 × 105 × 51
CurtainCurtain motors switched by mains power, low-voltage power or dry contact.0.13 A87 × 105 × 51
0–10 V dimmingTwo 0–10 V dimming outputs for dimmable drivers. Under 2 kW per circuit.0.152 A87 × 105 × 51
PWM dimmingTwo channels for 12–36 V LED strip. Under 100 W per channel.0.034 A87 × 105 × 51
InfraredControls the TV and stand-alone air-conditioners by IR; built-in temperature sensor reports room temperature.0.07 A69 × 105 × 51
Protocol conversionConnects other RS485 devices — air-con, thermostats and third-party equipment.0.12 A69 × 105 × 51

All modules: 12 V DC, DIN rail, storage −10 to 40 °C (master and 0–10 V dimming to 55 °C), 20–70 % relative humidity.

Want to see it working?

We can demonstrate the system, walk your rooms and existing systems with your team, and scope the project before anyone signs anything.